Description

Heavy Dye for selective staining:

Brilliant Peel was developed for specific staining of the inner limiting membrane (ILM). Specific staining of the ILM allows it to be clearly differentiated from the underlying retinal tissue and the epiretinal membranes. The surgically demanding removal of the ILM thus becomes easier and safer.

  • Selective staining of the ILM
  • Negative staining of the ERM and of residual vitreous fragments
  • Quick and intensive staining due to the sinking of the dye
  • Biocompatible solution for identifying residual ILM fragment
  • Without preserving agents

Use

Brilliant Peel was developed for specific staining of the inner limiting membrane(ILM). Specific staining of the ILM allows it to be clearly differentiated from the underlying retinal tissue and the epiretinal membranes. The surgically demanding removal of the ILM thus becomes easier and safer.

Composition and properties of one 0.5 ml syringe / vial:
0,125 mg Brilliant Blue G
0,95 mg Na2HPO4 x 2 H2O
0,15 mg NaH2PO4 x 2 H2O
4,1 mg NaCl
0,065 ml D2O
ad 0,5 ml water for injection purposes
Concentration:
0,25 g/l Brilliant Blue G
Density:
1,02 g/cm3

Literature:
1 Lüke C, et al.: Retinal tolerance to dyes, Br J Ophthalmol, 2005, 89, 1188-1191
2 Haritoglou C, et al.: Färbetechniken in der Makulachirurgie, Ophthalmologe, 2006, 103, 927-934
3 Ueno A, et al.: Biocompatibility of Brilliant Blue G in a rat model of subretinal injection, Retina, 2007, 27, 499-504
4 Enaida H, et al.: Brilliant Blue G selectively stains the internal limiting membrane – Brilliant Blue G assisted membrane peeling, Retina, 2006, 26, 631 – 636
5 Enaida H, et al.: Preclinical investigation of internal limiting membrane staining and peeling using intra­vitreal Brilliant Blue G, Retina, 2006, 26, 623-630
6 Hisatomi T, et al.: Staining ability and biocompatibility of Brilliant Blue G – preclinical study of Brilliant Blue G as an adjunct for capsular staining, Arch Ophthalmol, 2006, 124, 514-519
7 Goldman JM, et al.: Adjunct devices for managing challenging cases in cataract surgery – capsular staining and ophthalmic viscosurgical devices, Curr Opin Ophthalmol, 2007, 18, 52-57
8 Meyer CH, et al.: Historical considerations in applying vital dyes in vitreoretinal surgery: from early experiments to advanced chromovitrectomy, Expert Rev.
Ophthalmol., 2007, 71-77
9 Hiebl W, et al.: Substances for staining biological tissues: use of dyes in ophthalmology, Klin Monatsbl Augenh, 2005, 222, 309-311
10 Frank Schuettauf, Christos Haritoglou, Christian A. May, Robert Rejdak, Anna Mankowska, Wolfgang Freyer, Kirsten Eibl, Eberhart Zrenner, Anselm Kampik and Sebastian Thaler, Administration of Novel Dyes for Intra­ocular Surgery: An In Vivo Toxicity Animal Study, Invest Ophthalmol Vis Sci. 2006; 47:3573–3578
11 Rodrigues EB, et al.: Vital dyes for chromovitrectomy, Curr Opin Ophthalmol, 2007 May; 18(3):179-87
12 Furlani BA, et al.: Lutein and zeaxanthin toxicity with and without brilliant blue in rabbits. J Ocul Pharmacol Ther. 2014 Sep; 30(7):559-66. doi: 10.1089/jop.2013.0171. Epub 2014 Jun 5.
13 Tura A, et al.: Testing the effects of the dye acid violet-17 on retinal function for an intraocular application in vitreo-retinal surgery. Graefes Arch Clin Exp Opthalmol. 2014 Dec; 252(12):1927-37. doi: 10.1007/s00417-014-2761-9. Epub 2014 Sep 14.
14 Patent DE102012103097 A1
15 Sousa-Martins D, et al.: Use of lutein and zeaxanthin alone or combined with Brilliant Blue to identify intra­ocular structures intraoperatively. Retina. 2012 Jul; 32(7):1328-36. doi: 10.1097/IAE.0b013e318239e2b6.